ABB ACS880-11-021A-5 Variable Frequency Drive 11 kW

ABB ACS880-11-021A-5 Variable Frequency Drive 11 kW

share

ABB ACS880-11-021A-5 Variable Frequency Drive 11 kW

  • Detail
  • Parameters

When a motor is sometimes pushed by its own load, ACS880-11-021A-5 provides a practical ACS880-11 route for controlled energy regeneration and 11 kW operation. Its electrical envelope starts with a 3-phase AC 380–500 V supply and 50/60 Hz operation. Published figures are 21 A and 11 kW continuously without overload, 19 A/11 kW for light overload, and 14 A/7.5 kW in heavy-duty service. ABB identifies the enclosure as R3, IP21. Installation details can decide whether a good drive becomes a reliable system. Verify prospective short-circuit current, upstream protection, earthing, cable routing, motor insulation, EMC requirements, ventilation, ambient temperature, altitude, and available wall space. Regenerated power also needs somewhere to go. The supply network, other connected loads, transformer, and protection scheme must be reviewed so reverse power flow does not create an unpleasant surprise. From the viewpoint of a maintenance workshop manager, the model code is only the start. Required fieldbus, I/O, safety functions, filters, line equipment, documentation, certificates, local language, commissioning scope, and spare strategy should appear in the quotation. Long motor cables or sensitive bearings may call for additional output-side measures after an application review. IP21 suits protected indoor conditions defined by the project; it should not be treated as weatherproof. Google-friendly product content should answer buyer questions honestly. This page therefore distinguishes no-overload, light-overload, and heavy-duty ratings, explains a realistic use case, and avoids claiming guaranteed energy savings. It also avoids repeating the model name in every sentence. Search visibility is useful only when the visitor receives accurate context and can make a better technical decision. Before ordering ACS880-11-021A-5, compare current rather than kilowatts alone, confirm the exact supply voltage, and document whether the load will motor, regenerate, or alternate between both. Ask for a commercial offer based on the final configuration because options, approvals, logistics, and support can change price materially. When engineered around the real motion profile, this drive can become the composed energy manager behind a demanding oilfield pump test bench. Imagine a service center evaluating motors and rotating equipment. In that environment, the motor does not spend its entire life consuming energy. During part of the cycle, mechanics can drive the motor, turning it into a generator. The practical objective is to support controlled motoring and generating test points. ACS880-11-021A-5 approaches that moment like a methodical commissioning technician: attentive to direction, deliberate about transitions, and unwilling to treat every deceleration as unwanted heat. This perspective matters for a oilfield pump test bench. A conventional braking resistor may still be appropriate in some designs, but a regenerative architecture offers another route when cycles are frequent and returned energy can be accepted by the electrical system. Actual savings depend on duty cycle, load profile, network behavior, and system losses; they should be calculated from measured or credible operating data rather than assumed from marketing language. The ACS880-11 uses an IGBT supply stage and ABB direct torque control. Those technologies create engineering possibilities, not permission to skip system design. For this project, attention should center on instrumentation,

category
Regenerative Variable Frequency Drive
brand
ABB
Power supply voltage
3-phase AC 380–500 V
Power consumption
11 kW
frequency
50/60 Hz